CAN/CSA C802.1-13 (R2022) PDF

CAN/CSA C802.1-13 (R2022) PDF

Name:
CAN/CSA C802.1-13 (R2022) PDF

Published Date:
03/01/2013

Status:
Active

Description:

Minimum Efficiency Values for Liquid-Filled Distribution Transformers.

Publisher:
Canadian Standards Association / National Standard of Canada

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$42.9
Need Help?

Preface

This is the second edition of CSA C802.1, Minimum efficiency values for liquid-filled distribution transformers. It replaces the previous edition published in 2000.

The methodology of Total Ownership Cost (TOC) is presented as a means by which electric utilities may continue to purchase transformers that best suit projected provincial or local conditions. Such conditions include utility load, projected peak loads, generation capability and availability, generation reliability, and fuel prices, among other factors.

A given electric utility assigns multipliers to the no-load and load loss values which produce capitalized present values (PV) of those losses for the expected life of the transformer. The formula by which multipliers are assigned is known as the Loss Evaluation Formula. The present values of the losses are added to the first cost to derive the TOC of a given transformer. By using TOC to minimize overall costs, electric utilities have, at the same time, reduced losses in their transformers.

TOC methodology is not readily implemented in many non-utility applications and, in such cases, the minimum efficiencies provided in this Standard are more practical. The values given approximate those that typically arise when deriving efficiencies from the losses related to TOC calculations. Thus, though first cost may be increased, the user will amortize the increase because of the lower running costs resulting from lower losses. Utilities change their evaluation formulas as circumstances change, and the efficiency values in this Standard will be changed accordingly at appropriate intervals.

Scope

1.1
This Standard specifies energy efficiencies for liquid-filled distribution transformers. The total ownership cost (TOC) methodology is recommended as the means for achieving these energy efficiencies, particularly for use by electric utilities. This Standard also specifies an optimal method for nonutility users, based on a modified TOC methodology that meets the conditions of energy cost.

1.2
The transformers to which this Standard applies are single-phase and three-phase, 60 Hz, liquid-filled distribution transformers, rated at 10-833 kVA for single-phase and at 15-3000 k/VA for three-phase, insulation class 34.5 kV and less. Minimum low voltage ratings are shown in Table 1.

1.3
This Standard describes special features that influence efficiency, and provides for the necessary modifications to the tabulated efficiency values.

1.4
This Standard addresses the test methods and procedures for determining the transformer efficiencies.

1.5
This Standard does not apply to autotransformers, testing transformers, welding transformers, furnace transformers, rectifier transformers, network transformers, or grounding transformers. Also excluded are transformers with special core/coil designs required by dimensional constraints, transformers with tap ranges greater than 15%, transformers with frequencies other than 60 Hz, and step-voltage regulators.

1.6
In this Standard, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; and "may" is used to express an option or that which is permissible within the limits of the standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.


Edition : 2nd
File Size : 1 file , 660 KB
ISBN(s) : 9781771391580
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 17
Product Code(s) : 2422387, 2422599, 2422599
Published : 03/01/2013

History

CAN/CSA C802.1:23
Published Date: 12/12/2023
Minimum Efficiency Values for Liquid-Filled Distribution Transformers
$52.5
CAN/CSA C802.1-13 (R2022)
Published Date: 03/01/2013
Minimum Efficiency Values for Liquid-Filled Distribution Transformers.
$42.9
CAN/CSA C802.1-00 (R2011)
Published Date: 02/04/2001
Minimum Efficiency Values for Liquid-Filled Distribution Transformers.
$24.9

Related products

CAN/CSA C820-02 (R2012)
Published Date: 04/05/2002
Energy Efficiency Test Methods for Small Pumps
$24.3
CAN/CSA C239-02 (R2021)
Published Date: 01/01/2002
Performance Standard for Dusk-to-Dawn Luminaires
$24.3
CAN/CSA C13256-2-01 (R2020)
Published Date: 06/01/2001
Water-Source Heat Pumps - Testing and Rating for Performance - Part 2: Water-to-Water and Brine-to-Water Heat Pumps (Adopted ISO 13256-2:1998, first edition, 1998-08-15, with Canadian deviations)
$33

Best-Selling Products